<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>47617</ErrorNumber>
<ErrorFamily>Media Handler (APL)</ErrorFamily>
<ErrorMessage>
MDHAPL: Unable to &lt;request&gt;, check the &lt;mechanism&gt;
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Before initiating the user request, the state of the automatic pallet loader is
verified.  This error code indicates that the automatic pallet loader was in
an invalid state.
</text></DescriptionText>
<DescriptionText><text>
To open the APL, close the APL or measure the APL, it is expected that either
the pusher / picker are clear of the transfer table or the transfer table is
all the way up.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Reset the machine.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
The previous sequence failed.
</Cause>
<Cause>
A user has manually changed the state of the machine.
</Cause>
<Parameter>
request  -
Identifies the request that cannot be performed.
</Parameter>
<Parameter>
mechanism  -
Identifies the mechanism that was in an unexpected state.
</Parameter>
<LastModified>
29-Mar-2007
</LastModified>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:52 2008 PST
</Updated>
<Links>
</Links>
</Error>